CubiScan 210-SS small

CubiScan 210-SS

  • Physical Specifications

    Width Approximately 5 lbs (2.3 kg) per sensor

  • Performance Specifications

    Detectable Object Shape Cuboid objects

    Useful Field of View Maximum 70 degrees

    Measurement Increment Non-LFT Version (L x W x H) up to 393.7 fpm (2 mps): 0.2 in (5 mm); 394-600 fpm (2-3.05 mps): 0.4 x 0.4 x 0.2 in (10x10x5 mm)

    Measurement Increment LFT Version (L x W x H) Greater than or equal to 2 in (50 mm)

    Minimum Conveyor Speed Non-LFT and LFT Versions 0.25 x 0.25 x 0.2 in (6 x 6 x 5 mm)

    Object Interval LFT and Non-LFT Version Greater than or equal to 2 in (50 mm)

    Minimum Conveyor Speed Non-LFT Version 10 fpm (0.05 mps)

    Minimum Conveyor Speed LFT Version 50 fpm (0.25 mps)

    Maximum Conveyor Speed LFT and Non-LFT Version 600 fpm (3.05 mps)

    Object Remission 10 – 200%

  • Measurement Range

    Minimum Object Size Non-LFT and LFT Versions (L x W x H) 2.4 x 2.4 x 2.4 in (61 x 61 x 61 mm)

    Minimum Object Size Non-LFT Version (L x W x H) 2 x 2 x 2 in (50 x 50 x 50 mm)

    Minimum Object Size LFT Version (L x W x H) 3 x 3 x 2.4 in (76 x 76 x 61 mm)

    Maximum Object Size LFT and Non-LFT Versions (L x W x H) 60 x 48 x 36 in (1524 x 1220 x 914 mm)

  • Other

    Sensor Type Non-LFT Version SICK VMS 410

    Object Type LFT Version SICK VMS 510

    Optical Indicators 6 LEDs per sensor

    Host Interfaces RS-232 or RS-422, Ethernet, Profibus, and Devicenet, Output format is user-definable

    Laser Diode (Wavelength) Visible light (650 nm)

    Laser Power Max.7.5 mW

    Laser Class of the Device Class 2 (complies w/ 21 CFR 1040.10 w/ exception of the deviations per Laser Notice #50, 07/26/2001)

    Enclosure Rating/Protection Class IP 20 (according to DIN 40050); with plug cover IP 65

    Housing Aluminum die-cast

    Output Data Non-LFT Version Maximum dimensions (length, width, height); box volume)

    Output Data LFT Version Max dimensions (L, W, H); Box volume

    EMS Test In compliance with EN 61000-6-2:2001, EN 61000-6-4:2001

    Operating Voltage/Power Consumption 24 V DC +- 15%/max. 50W

    Vibration Shock Test In complliance with EN 60068-2-6, -27, -29, -64

    Temperature (Operation/Storage) 23 to 104 degrees fahrenheit / -4 to 158 degrees fahrenheit (-5 to 40 C / -20 to 70 C)